Rubber Products Test Methods

Aug 01, 2021

Leave a message

Rubber products test methods

Measure Shore A hardness according to DIN 53505

This method was invented by Albert F. Shore in the 1920s and is currently the most commonly used method for measuring elastic colloids.

The surface of the detector must be a flat and parallel surface. The test number must be read after staying for 3 seconds. Therefore, the measurement of Shore A is basically used for material development and the release of formula raw materials. For tangible materials, it can only This method can only be used on the premise that it has sufficient thickness and flat surface. Shore A is suitable for hardness measurement from 10 to 90. Hardness exceeding 90 must be measured by Shore D. It is not suitable for the hardness measurement of elastic colloids. .

Hardness testing equipment

-The hardness tester must meet the following requirements, and must indicate the Shore A hardness or the Shore D hardness tester, and also indicate the manufacturer's identification and production number.

-The scale division value must have a hardness unit and the interval between the scales must be ≥1mm.

-The shape and size of the extruded body and the surface of the bracket must conform to Figure 1.

-The elasticity value of the tester is calculated by applying force to the extruded body, which is generated by the weight.

The theoretical value of elasticity is listed in Table 1, rounded to 5mN.

-Shore A and Shore D hardness testers allow a tolerance of ±1. The internal use of the instrument must be constantly monitored by the user. When used to detect binding data (such as acceptance testing, etc.), the tester must be based on DIN51220 is tested once a year by an official testing agency.

Body measurement

shape:

The diameter of the test area must be ≥35mm, it must be smooth and flat. The surface of the test body must be coated with talc when testing the Shore A hardness. The thickness of the test body must be ≥6mm

Hardness measurement

Hardness is one of the important parameters in rubber technology. The German Freudenberg Process Seals organization has clearly defined the standard hardness of all elastomer materials (such as 70EPDM 291). Although there are many different standard methods to measure hardness. But always To measure the depth that a fixed detector can squeeze into the colloid under a certain force.

Volume change measurement

Liquids and gases affect elastic colloids in different ways. Here people distinguish between chemical media and physical media. Chemical media react with elastic colloids and can irreversibly change its properties, such as separation in the component chain Link points (= loss of elasticity) or by forming more link points (= material hardens). Some media will also attack the molecular chain of elastic colloids and destroy it. Physically active media can cause two processes to occur at the same time:

a. Absorb the medium through elastic colloid

b. Separate the soluble mixture components (such as softeners) from the elastic colloid.

This process can be determined by detecting the change in volume, if a is greater than b, it is expansion, or if b is greater than a, it is shrinking.

The expansion process is generally irreversible.

The degree of volume change is restricted by the following factors:

-Type of medium

-The structure of elastic colloid

-temperature

-thickness

-The relaxation state of the colloid (the effect is greater in the relaxation state and less in the compression state)

Because of the network molecular structure of elastic colloids, the expansion is limited, that is, they will not change after reaching a certain marginal value.

Squeeze traces of elastic colloid

According to DIN 53 517 or DIN ISO 815 or ASTM D 395, the traces of extrusion deformation are measured under continuous extrusion. It reflects the deformation of the tested material. There are many test methods for elastic colloids, such as tensile strength. Explain the quality and characteristics of the material. Extrusion marks are an important factor to pay attention to before use. Especially when used for sealing or backing plates, indentation is an important parameter.

Squeeze marks

Indentation is a standard for evaluating the rebound of elastic colloids after a long period of continuous squeezing.